Monarplan Pipe Boots

Pipe Penetrations

 
  • Use Monarplan pre-fabricated pipe fittings where possible.
  • Remove any existing lead flashing, old paint, and rust where applicable and clean surface to receive membrane flashing.
  • Cut pre-fabricated pipe fitting to the appropriate pipe diameter and slide into position.
  • Install mastic sealant between the Monarplan Pipe Fitting and the pipe and secure with a stainless steel clamping ring (eg. jubilee clip).
  • Where pre-fabricated pipe fittings are not practical, wrap the pipe with unreinforced Monarplan PVC D in accordance with the appropriate detail.

Pipe-Penetrations  

Key

1. Pipe ø 50-125mm.
2. Stainless steel clamping ring.
3. Substrate.
4. Monarplan PVC membrane.
5. Monarplan pre-moulded pipe fitting

6. Insulation.
7. Washer & fastener.
8. Hot air weld min. 40mm.
9. Mastic sealant.
10. Vapour control layer.

 

Hot Pipes

Pipe penetrations that exceed 50°C require an oversize insulated sleeve to flash to.

Associated Monarplan Products

Pipe Boot

 

 

Monarplan pipe flashing    

 